Rotary Thermoplastic Seals-Application failures-Gap extrusion

  Jul 06, 2020

  Leave a message

 

Rotary Thermoplastic Seals-Application failures-Gap extrusion






Failure mode

gap extrusion and seal break

 

Failure cause

gap behind seal too big

too high pressure for seal

 

Remedial measures

reduce clearance fit behind seal

reduce operating pressure

install more stable seal profile or material