linear&reciprocating-Application failures-leakage without failure mode

  Jul 03, 2020

  Leave a message

 

linear&reciprocating-Application failures-leakage without failure mode


Failure mode

no failure mode, but leakage occurs

 

Failure cause

contact loss of seal lip due to insufficient low temperature performance of seal recovery

reduced recovery of seal material

seal installation wrong, opposite to pressure side

 

Remedial measures

change to more low temperature flexible material

material with higher elasticity

avoid failures of concentricity of components

check correct seal installation