Linear&reciprocating-Ageing-crack formation

  Jul 01, 2020

  Leave a message

 

Linear&reciprocating-Ageing-crack formation


Failure Mode

Crack formation

 

Failure cause

Chemical incompatibility of fluid and seal material

Thermal overload

 

Remedial measures

Change to suitable seal material

Reduce operating temperature